Bar + Vacuum chuck two-in-one, with high-precision imported bar, suitable for film substrate Spreader; base size 480 * 630mm, coating speed 1~ 200mm/s; external vacuum pump.
zy TBJ-A3-DJ2 Automatic Film ApplicatorPacking list
SKU
NB036189
Coating method
Rod
Mayer Rod Thickness Range
1-571.5 μm (Spreader thickness according to bar model)
Mayer Rod Accuracy
±0.001mm
application width
480mm
Coating speed
5-200Mm/s (< 5mm/s can be customized)
Vacuum pump configuration
external
vacuum aperture
Φ1.2mm
Control mode
Touch screen control
Substrate clamping method
Vacuum adsorption
Total power consumption
2060W
Host Power Supply
220V 50Hz
Dimension
852*645*500mm
Machine Weight
65Kg
Bottom plate material
aluminum alloy
Vacuum pump size
380*180*280mm
Optional Accessories
Leakage tank, substrate fixture, trimming horizontal height support foot device, Glass plate, silicone pad and Weight (for applications with uneven thickness of Spreader substrate), application width control baffle
Bar + Vacuum chuck two-in-one, with high-precision imported bar, suitable for film substrate Spreader; base size 480 * 630mm, coating speed 1~ 200mm/s; external vacuum pump.
product description
The touch laboratory TBJ-A wire rod coating testing machine is a newly upgraded product that is carefully designed to coat precise wet films on different substrates. It can repeatedly and continuously prepare smooth, flat and flawless coatings. After testing samples, the equipment has been favored by many familiar companies, research and development institutions, and colleges and universities after it was put into the market.
This automatic coating machine comes standard with one domestic (CN) wire rod and one imported wire rod with a precision up to 1μm.
[Note]Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
QIs this Film Applicator available on aluminum foil?
A
Yes, this one has vacuum adsorption and can be used for aluminum foil substrates.
QPET film is naturally curled, how to film?
A
Vacuum adsorption can be used, the film adsorption on the Drawdown Vacuum Plate, and then with the wire rod film.
QWhat is the baseplate size of this small laboratory coater?
A
Hello, it is 480 * 630mm.
QWhat is the allowable viscosity of the Spreader material for this coater?
A
The allowable range of film viscosity is generally determined by the Moulding device. The viscosity of the wire rod generally does not exceed 1000cp, and the doctor blade has no limit. But the accuracy of the wire rod is higher. In addition, due to the heating function, the viscosity of some materials decreases with the increase of temperature, so it is necessary to comprehensively consider the requirements of materials, substrates, film thickness and preparatory purposes. For details, please consult NBchao customer service.