China

LEICI DDSJ-307F Conductivity Meter conductivity Electrical resistivity TDS salinity, temperature 1.0 class

SE
Level 1.0, measurement conductivity, Electrical resistivity, TDS, salinity value, temperature, standard composite Conductivity Detector electrode, electrode holder, dust cover and calibrated solution, using high definition LCD, standard composite Conductivity Detector electrode, electrode holder, dust cover and calibrated solution
$539.00/set
PromotionLoading...
Coupon
Model:

LeiCi DDSJ-307F Conductivity MeterSPEC

LeiCi DDSJ-307F Conductivity MeterDetails

LeiCi DDSJ-307F Conductivity MeterPacking list

SKU
NB039034
Instrument level
Level 1.0
Measurement parameters
Electrical resistivity, conductivity, TDS, salinity, temperature
Conductivity range
0.000μS/cm~ 1000mS/cm
Resolution
0.001 μS/cm, automatically switched according to the range
Electrical resistivity range
5.00Ω ·cm~20.00MΩ ·cm
Electronic unit reference error
±1.0%FS
TDS range
0.00mg/L~300g/L
Resolution
0.01Mg/L, automatically switched according to the range
Electronic unit reference error
±1.0%FS
Salinity range
(0.00~8.00)%
Resolution
0.01%
Temperature Measurement Range
-5.0~110.0℃
Resolution
0.1℃/0.1℉
Electronic unit error of indication
±0.2 ℃
Power
Power adapter (input: AC100~240V, output: DC9V)
size
242*195*68mm
Weight
0.9kg
DDSJ-307F
Conductivity Meter
Level 1.0, measurement conductivity, Electrical resistivity, TDS, salinity value, temperature, standard composite Conductivity Detector electrode, electrode holder, dust cover and calibrated solution, using high definition LCD, standard composite Conductivity Detector electrode, electrode holder, dust cover and calibrated solution
LEICI DDSJ-307F Conductivity Meter conductivity Electrical resistivity TDS salinity, temperature 1.0 class Picture

main feature

● Adopt high-definition LCD with clear display

● Temperature units are optional: ℃ and °F;

● Reference temperature 20℃ or 25℃ optional

●Supports functions such as power-on self-diagnosis, automatic shutdown, power-off protection and factory reset

● Support firmware upgrade function, allowing function expansion and personalized requirements

●Support IP54 protection level

● Comes standard with composite conductivity electrode, electrode holder, dust cover and calibration solution


Intelligent detection and automatic identification

● Intelligent identification of end points, supporting automatic reading, scheduled reading, scheduled interval reading, and manual reading

●Support automatic/manual temperature compensation

● Automatically identify 4 kinds of GB conductivity standard solutions and support 1-3 point conductivity electrode calibration

●Supports multiple conductivity compensation methods such as non-compensation, linear, pure water compensation, etc.

● Supports automatic frequency switching, and is equipped with a 1.0 constant electrode that can cover the full range of measurements (it is recommended to use a 0.1 constant or 0.01 constant conductivity electrode for measurement of samples below 20 μS/cm)


Data management, information traceability

● Support data storage (500 sets each), review, deletion, transmission and printing

● Comply with GLP and realize data traceability

● Equipped with RS-232 interface, supports connection to standard RS-232 serial port printer, and directly prints measurement results. The printing format is optional.

● With USB interface, it can be connected to PC through special communication software to realize data transmission.


FAQ
QI want to measure the conductivity of pure water, is it appropriate to use LEICI DDSJ-307F?
A Suitable! This Conductivity Meter Measurement range starts at 0.000 μS/cm and is especially suitable for low conductivity samples such as pure water. It also has automatic Frequency switching, and with 0.1 or 0.01 constant Conductivity detector electrodes, it can accurately measure pure water samples below 20 μS/cm.
QCan This Conductivity Meter Measure the Resistance of Ultrapure Water?
A 307F is recommended.
QWash the potassium and sulfur in the polymer with high-purity water, and then measure the conductivity of the cleaned solution to measure the conductivity of potassium and sulfur in the water. Is there a recommendation?
A Not applicable
QFor water paint, which Conductivity Meter is used for liquid resistance?
A This one is fine.
Knowledge