China

CHINA Constant Humidity Cyclic Chamber constant temperature and humidity machine NBC-HW-150 -40 ℃/150L

Touch screen operation, Taikang compressor imported from France, temperature control -40 ℃~ 150 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity control range 20~98% RH, working volume 150L, 304 stainless steel material.
Certificate

JiangKai NBC-HW-150(-40℃) Constant Temperature and Humidity ChamberSPEC

JiangKai NBC-HW-150(-40℃) Constant Temperature and Humidity ChamberDetails

JiangKai NBC-HW-150(-40℃) Constant Temperature and Humidity ChamberPacking list

SKU
NB042198
Interior Volume
150L
Temperature range
-40~150℃
Temperature Fluctuation
0.5℃
Humidity control range
20~98%R.H
Humidity Deviation
≤3%
Interior size
500*500*600mm
Dimensions
1000*1120*1500mm
Temperature deviation
≤2℃
Heating rate
RT +~ 150 ℃ Technologies 40min (no-load nonlinear)
Cooling rate
RT + → -60 ℃ Technologies 60min (no-load nonlinear)
Humidity stability
3%R.H
Chamber material
Stainless steel plate (SUS #304)
Enclosure Material
Stainless steel plate atomization treatment (SUS #304) or cold plate paint (optional)
Insulation material
Rigid Polyurethane Foam and Glass Cotton
Air supply circulation system
(1) 1 90W motor; (2) Stainless steel extended shaft; (3) Multi-wing fan blade (SIRCCO FAN)
Box door
Single door, single window, open left, handle on the right
Box door window
260X340x40mm, 3 vacuum layers
Compressor
French original imported fully dense compressor
refrigerant
Environmentally friendly refrigerant R404A
Condenser
Fin type with heat dissipation motor
Evaporator
Fin type multi-stage automatic load Capacity adjustment
Miscellaneous Accessories
Drying agent, Refrigerant Flow rate window, Expansion valve
expansion system
Capacity-controlled refrigeration system
NBC-HW-150(-40℃)
Constant Temperature and Humidity Chamber
Touch screen operation, Taikang compressor imported from France, temperature control -40 ℃~ 150 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity control range 20~98% RH, working volume 150L, 304 stainless steel material.
CHINA Constant Humidity Cyclic Chamber constant temperature and humidity machine NBC-HW-150 -40 ℃/150L Picture

fulfill the standard

Performance indicators comply with the requirements of GB5170, 2, 3, 5, 6-95 "Basic Parameter Calibration Methods for Environmental Test Equipment for Electrical and Electronic Products Low Temperature, High Temperature, Constant Humid Heat, and Alternating Humid Heat Test Equipment"

Basic Environmental Testing Procedures for Electrical and Electronic Products Test A: Low Temperature Test Method GB 2423.1-89 (IEC68-2-1)

Basic Environmental Testing Procedures for Electrical and Electronic Products Test B: High Temperature Test Method GB 2423.2-89 (IEC68-2-2)

Basic Environmental Testing Procedures for Electrical and Electronic Products Test Ca: Constant Humidity and Heat Test Method GB/T 2423.3-93 (IEC68-2-3)

Basic environmental testing procedures for electrical and electronic products Test Da: Alternating damp heat test method GB/T423.4-93 (IEC68-2-30)

Applications

It mainly conducts high temperature, low temperature and alternating humidity and heat tests on electronics, electrical appliances, household appliances, automobiles and other product parts and materials under constant humidity and heat conditions to test their various performance indicators and adaptability.

Refrigeration system

A. Compressor: Fully sealed compressor imported from France

B. Refrigerant: environmentally friendly refrigerant R404A

C. Condenser: fin type with cooling motor

D. Evaporator: fin type multi-stage automatic load capacity adjustment

E. Other accessories: desiccant, refrigerant flow window, expansion valve

F. Expansion system: capacity controlled refrigeration system

Control System

Original imported from South Korea, full Chinese LCD 7-inch Korean 880 display LCD touch panel, screen dialogue input data, temperature and humidity can be programmed at the same time, curve display, set value/display value curve. Various alarms can be displayed separately. When a fault occurs, the fault can be displayed on the screen to eliminate faults and misoperations. Multiple sets of PID control functions and precise monitoring functions are displayed on the screen in the form of data.

1.Controller specifications:

a. Accuracy: temperature ±0.1℃, humidity ±1%RH

b. Resolution: temperature ±0.1, humidity 1%RH

c. Temperature slope: 0.1~9.9 can be set

d. With upper and lower limit standby and alarm functions

e. Temperature and humidity input signal selection PT 100Ω×2 (dry bulb and wet bulb)

f. Temperature and humidity conversion output: 4~20MA

g. 6 sets of PID control parameter settings, automatic PID calculation, automatic correction of wet and dry bulbs

2.Screen display function:

a. Touch input, display options directly on the screen

b. Temperature and humidity setting (SV) and actual (PV) values ​​are directly displayed (in English)

c. Can display the currently executing program number, segment, remaining time and number of cycles

d. Operation accumulated time function

e. The temperature and humidity program setting values ​​are displayed in a graphic curve, with the function of real-time display of program curve execution.

f. With a separate program editing screen, you can directly input temperature, humidity and time.

3. Program capacity and control functions:

a. Usable program groups: maximum 100 groups

b. Usable memory capacity: 5000SEGMENTS in total

c. Repeatable execution of commands: each command can be executed up to 9999 times

d. The program is created in a conversational style, with functions such as editing, clearing, etc.

e.SEGMENTS time setting 0~530Hour59Min

f. It has power-off program memory and can automatically start and resume program execution after power is restored.

g. Graphical curves can be displayed in real time when the program is executed

h. With date and time adjustment functions

i. Button and screen lock (LOCK) function

Main electrical accessories of equipment

 Cooling System:Material namequantity
compressorTaikang (France)1 set
condenserFin type equipped with cooling fan (Donghua)1 set
EvaporatorCustomized (medium force)1 set
Expansion valveDanfoss/Honeywell (Denmark)2 sets
The electromagnetic valveDanfoss (Denmark)2
The electromagnetic valveSaginomiya (Japan)2
pressure controllerSaginomiya (Japan)1
oil separatorALCO (USA)1
filterALCO (USA)1
Refrigerant: R404AHoneywell (USA)Appropriate amount
Copper pipes and other miscellaneous itemsTaishun (Taiwan, CHINA)1 item
control system:Material namequantity
Temperature and humidity control instrument:TEMI880 (South Korea) color screen touch1 set
Over-temperature protection instrument :RKC (Taiwan, CHINA)1
Temperature Sensor :Pt1002
Humidity Sensor :Pt1001
contactorTaian (Taiwan, CHINA)2
heat protectorTaian (Taiwan, CHINA)1
solid state relayANV(Taiwan, CHINA)3
time delay relayANV(Taiwan, CHINA)2
Intermediate relayOmron (Taiwan, CHINA)several
Heater1 Kw (customized)2 pieces
Humidification tube1Kw (customized)1 set
Switching power supply (leakage protection)Lande (Taiwan, CHINA)1 set
Terminal blockNIM (Japan)1 item
transformercustom made1
R232 communication interface and softwareEquipped with monitoring and data recording (optional 1500.00)1 set
control switch panelcustom made1 item
 Audible alarmTaian (Taiwan, CHINA)1 set
heater protectionTaide (Taiwan, CHINA)1 set
Fluorescent lamp ballastOSRAM (Germany)1 set


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Knowledge