Italy

HANNA HI88713 Microcomputer multi-range Turbidimeter (ISO standard)

SE
Measurement range: 0~1000NTU, resolution: 0.01FNU, 0.1FNU, 1FNU, measurement accuracy: reading +/- 2%, IR LED dedicated Infrared source, in line with 1S07027 measurement standard; with CAL CHECK ™ performance verification function, built-in turbidity calibrate point.
$3124.00/set
PromotionLoading...
Coupon
Model:

HANNA HI88713 Turbidity MeterSPEC

HANNA HI88713 Turbidity MeterDetails

HANNA HI88713 Turbidity MeterPacking list

SKU
NB045264
Measurement range -FNU turbidity mode
0.00 to 9.99、10.0 to 99.9、100 to 1000FNU
Resolution-FNU turbidity mode
0.01FNU、0.1FNU、1FNU
Measurement Accuracy -FNU turbidity mode
+/- 2% reading (ignoring stray light error);
Measurement range -FAU turbidity mode
10.0 to 99.9FAU、100 to 4000FAU
Resolution-FAU turbidity mode
0.1FAU、1FAU
Measurement Accuracy -FAU turbidity mode
Reading +/- 10%
Measurement range - turbidity nonlinearity
0.00 to 9.99、10.0 to 99.9、100 to 1000NTU;0.00 to 9.99、10.0 to 99.9、100 to 245EBC
Resolution - turbidity nonlinearity
0.01NTU、0.1NTU、1NTU;0.01EBC、0.1EBC、1EBC
Measurement Accuracy - turbidity nonlinearity
+/- 2% + stray light error of reading (@25 ℃/77 ° F)
Measurement range - turbidity linearity
0.00 to 9.99、10.0 to 99.9、100 to 4000NTU;0.00 to 9.99、10.0 to 99.9、100 to 980EBC
Resolution - turbidity linearity
0.01NTU、0.1NTU、1NTU;0.01EBC、0.1EBC、1EBC
Measurement Accuracy - turbidity linearity
+/- 2% of reading + stray light error (≤ 1000NTU); +/- 5% of reading (> 1000NTU) (@25 ℃/77 ° F)
range conversion
Automatic range conversion
Turbidity Repeatability
+/- 1% of the reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC), whichever is greater
minimum detection limit
<0.1NTU(0.05EBC)
Method/standard
Compliant with ISO7027 turbidity measurement standard
Measurement mode
Ordinary measurement, continuous measurement, average measurement
Calibrated mode
Manual calibration with built-in standard calibrating points: < 0.1, 15, 100, 750FNU and 2000NTU
Optical inspection system
Custom Dedicated Receiver & Light source System
data management
USB Interface, 200 sets of measurement Data storage
Power mode
230V/50Hz 20W; if you don't do how to operate it for 15 minutes, it will automatically shut down.
Operating Environment
0 to 50°C(32 to 122°F),RH max 95% 无冷凝
Size Weight
Host size: 230 × 200 × 145mm, host Weight: 2.5kg
HI88713
Turbidity Meter
Measurement range: 0~1000NTU, resolution: 0.01FNU, 0.1FNU, 1FNU, measurement accuracy: reading +/- 2%, IR LED dedicated Infrared source, in line with 1S07027 measurement standard; with CAL CHECK ™ performance verification function, built-in turbidity calibrate point.
HANNA HI88713 Microcomputer multi-range Turbidimeter (ISO standard) Picture

Introduction

Hl88713 is a high-precision multi-range turbidity laboratory Tester that can measure FNU, FAU, NTU and EBC in different units. It is suitable for the water industry, beer industry, etc.; it has different measurement range options, and low turbidity range (0.00to 9.99 FNU) and high turbidity range (0.0to 4000 FNU) {1 NTU=1 FNU}, especially in the low value range, it has extremely high accuracy and precision, and is suitable for the analysis of samples with different concentrations in different fields. Measurement. Hl88713 uses a special customized infrared light surge, which complies with the 1S07027 turbidity measurement standard. The microprocessor calculates the turbidity value through the light intensity reaching the photoDetector; it effectively corrects color interference and has chromaticity compensation and automatic light source compensation functions. It avoids interference caused by light source fluctuations and eliminates the need for frequent calibration. The lowest detection limit for turbidity is determined by the concentration of stray light, which is scattering not caused by suspended particles. The unique optical path design of the Hl88713 multi-range Turbidimeter effectively reduces stray light, allowing the instrument to ensure excellent accuracy, precision and reliability in low turbidity measurements.

Humanized system operation, simple and accurate

With good GLP function, you can easily check detailed calibration information. The instrument has a large screen display, user-friendly interface, detailed help information and operation prompts, allowing you to complete various operations step by step under the guidance of the instrument. The storage function of the large capacity can store 200 sets of measurement data and can be viewed at any time. If you want to perform further data processing, you can use the USB data interface of the instrument and purchase the Hl92000-13 data processing software to transfer the data to the computer for subsequent analysis. 

Characteristics 

  • Large backlit LCD display, stable indicator marks, and on-screen operation prompts;

  • Multiple ranges, automatic range conversion, three measurement modes;

  • IR LED special infrared light source, conforms to 1S07027 measurement standard;

  • CAL CHECK™ performance verification function with built-in turbidity calibration point;

  • GLP management function, query settings, calibration, time and other information;

  • USB data interface, 200 sets of data storage, data management.

FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Knowledge
Standard