Italy

HANNA HI98308 Ultra low range conductivity EC Tester

SE
Automatic temperature compensation, replaceable electrodes, conductivity range 0.0~99.9 μ S/cm, for monitoring deionized water, distillation water, mineral water.
$203.00/set
PromotionLoading...
Coupon
Model:

HANNA HI98308 Ultra low range conductivity EC TesterSPEC

HANNA HI98308 Ultra low range conductivity EC TesterDetails

HANNA HI98308 Ultra low range conductivity EC TesterPacking list

SKU
NB045325
Measurement range
0.0 to 99.9μS/cm
resolution
0.1μS/cm
Accuracy @25 ℃
±2%F.S.
Calibrated mode
Manual calibration (recommended calibrating point: 84 μS/cm)
Temperature compensation
Automatic temperature compensation: 0.0 to 50.0 ℃, compensation coefficient β = 2%/℃
Standard electrode
Built-in EC electrode
Power mode
4 * 1.5V AA button battery
Adapt to the environment
0℃ to 50℃(32℉ to 122℉);max 95% RH
Host size
175*41*23mm
Host Weight
95g
HI98308
Ultra low range conductivity EC Tester
Automatic temperature compensation, replaceable electrodes, conductivity range 0.0~99.9 μ S/cm, for monitoring deionized water, distillation water, mineral water.
HANNA HI98308 Ultra low range conductivity EC Tester Picture

Introduction

HI98308 (PWT) is used to monitor deionized water, distilled water, and mineral water.

Features

  • Automatic temperature compensation, fast response temperature probe

  • Uniquely designed high-performance bipolar graphite electrode

  • Replaceable electrodes reduce usage costs


FAQ
QI want to measure the purity of distillation water. What instrument should I use?
A Recommended HANNA HI98308 Conductivity Meter, it is specially used to monitor distillation water, deionized water and other pure water, Measurement range 0.0~ 99.9 μS/cm just cover the low conductivity characteristics of pure water, automatic temperature compensation can ensure accurate data.
QThe laboratory needs to quickly test the conductivity of mineral water. Is there any recommendation?
A HI98308 is recommended, which uses a rapid Response temperature sensor and Graphite electrode, the measurement is stable and rapid, and the electrode can be replaced, and the long-term use cost is low, which is suitable for conventional water quality testing such as mineral water.
QIs this Conductivity Meter complicated to operate? Does it need to be calibrated frequently?
A HI98308 is easy to operate and supports single-point Manual calibration. Generally, it can be calibrated once with 84 μS/cm standard liquid. Daily use of direct reading, portable design can be operated with one hand, especially worry-free.
Standard