âEquipped with complete purification unit:
a. Tap water pre-purification unit;
b. Two-stage reverse osmosis desalination pre-purification unit for tap water;
c. Sterile pure water storage unit (non-pressure barrel type);
d.Ultra-purification unit;
e. Post-processing unit;
f. Fully intelligent monitoring unit.
âFully intelligent control system, supports multi-language mode, multi-user use, and independent pricing. True color LCD touch screen, graphical human-machine interface, operation and information online query in one step. (Non-RS232 port external computer operation query)
âMulti-point full-line monitoring: source water quality/pressure/temperature/flow; pre-purification unit water flux accumulation; pre-purified water quality/water consumption; pure water storage capacity; ultrapure water quality/water consumption accumulation; UV life; Ultrafiltration water flux accumulation.
âThe setting of actual consumable operation confirmation data serves as a standard for online diagnosis to facilitate maintenance; reminders are displayed for consumable replacement. (Non-time set consumable reminder)
âAbnormal operation of the entire system (water quality and quantity of source water, pre-purified water, ultrapure water) online self-diagnosis, warning or automatic system stop operation, important system components (solenoid valve, booster pump, UV lamp, sensor, etc.) Intelligent fault judgment and online replacement instructions.
âTwo-stage reverse osmosis depth desalination, the raw water quality is less than 2000μs, the system salt removal rate is â¥99.5%, and the raw water utilization rate reaches 60-80%.
âTertiary water/ultrapure water are each quantitatively drawn. The quantitative water drawing range is any integer volume, and the error is ±2ml (<500ml) or 1% (â¥500ml).
âThe Zhencai display screen displays water quality, total water intake and flow rate online, allowing users to understand the water intake status at a glance.
âAll monitoring data of the entire system are collected in real time and can be viewed online without the need for external computer storage. The data storage capacity can reach more than one year.
âData is uploaded to the cloud service center via USB every month for backup and diagnosis. Professional engineers will retrospectively analyze the uploaded data and provide diagnostic reports and preventive maintenance recommendations to customers based on the analysis results.
âThe plug-and-play modular design of the system purification unit and components makes calibration, maintenance, cleaning, disinfection, and sampling during system validation easier.


1) The whole machine is imported with original packaging and complies with the standards of NSF and Water Quality Association of the United States;
2) Strictly implement the ISO9001:2008 quality management system to ensure uniform and stable product quality;
3) Standardized module design and production to ensure product maintenance and repair;
4) A "preventive maintenance" after-sales service system, combined with the Ecopu EMOAS network management platform, computerizes the historical operating status of the equipment to ensure long-term stable operation of the equipment.
Glass dish cleaning, titrator, particle analyzer, pH measurement, spectrophotometry, surface tension experiment, autoclave, biochemical oxygen demand, heating pot, hydroponics, Kedar analysis. Stability testing. Water for basic physical and chemical experiments such as wind erosion resistance Tester, chemical oxygen demand, dissolution test, aquarium, etc.
Serial number | name | Model specifications | quantity | unit | Remark |
1 | TAP-CLEAR module | Raw water treatment capacity: 20,000-30,000 L | 1 | Group | AIC |
2 | DP-RO module | Water production: 5 L/h | 1 | Group | AIC |
3 | ULTRA-CLEAR MODULE | Ultrapure water treatment capacity: 8000 L | 1 | Group | AIC |
4 | Patented sterile pure water storage device | 10L | 1 | set | AIC |
5 | terminal filter | 0.22μm | 2 | set | Sartorius |
6 | SMART-ANGEL Fully intelligent monitoring system | Supporting | 1 | set | AIC |
7 | touch system | Supporting | 1 | set | AIC |
| model | AD3L-05-03/08-BE | AD3L-08-03/08/16-BE | AD3L-16-03/08/16/24-BE | AD3L-05-03/08-CE | AD3L-08-03/08/16-CE | AD3L-16-03/08/16/24-CE | AD3L-05-03/08-OR | AD3L-08-03/08/16-OR | AD3L-16-03/08/16/24-OR | |||
| application | Ultrapure water machine for biological laboratories | Ultrapure water machine suitable for physical and chemical tests | Ultrapure water machine suitable for basic physical and chemical experiments | |||||||||
| Incoming water source | Municipal tap water inflow, raw water hardness <450ppm, raw water conductivity <2000 u s/cm@25℃, raw water pressure: 1-5kg; water temperature: 5-35℃ | Incoming tap water, raw water hardness <450ppm, raw water conductivity <2000 u s/cm@25℃, raw water pressure: 1-5kg; water temperature: 5-35℃ | Incoming tap water, raw water hardness <450ppm, raw water conductivity <2000 u s/cm@25℃, raw water pressure: 1-5kg; water temperature: 5-35℃ | |||||||||
| Pure water product* | 5L/h | 8 L/h | 16 L/h | 5L/h | 8 L/h | 16 L/h | 5L/h | 8 L/h | 16 L/h | |||
| Ultrapure water product* | 3/8T | 3/8/16T | 3/8/16/24T | 3/8T | 3/8/16T | 3/8/16/24T | 3/8T | 3/8/16T | 3/8/16/24T | |||
| Water flow rate* | 1-1.5 L/min | 1-1.5 L/min | 1-1.5 L/min | |||||||||
| Water production index | Pure water: resistivity â¥0.2 MΩ.cm@25℃, Yougan CHINA laboratory water specification GB6682-2008 third-level water standard; | Pure water: resistivity â¥0.2 MΩ.cm@25℃, Yougan CHINA laboratory water specification GB6682-2008 third-level water standard; | Pure water: resistivity â¥0.2 MΩ.cm@25℃, Yougan CHINA laboratory water specification GB6682-2008 third-level water standard; | |||||||||
| Ultrapure water: resistivity 18.25 MΩ.cm@25℃, TOC (processed by DP-RO) <5ppb, microorganisms <1cfu/ml, particles (>0.2μm) <1/ml, bacterial endotoxin <0.001EU/ ml. | Ultrapure water: Resistivity 18.25 MΩ.cm@25℃, TOC (processed by DP-RO) <10ppb, microorganisms <1cfu/ml, particles (>0.2μm) <1/ml. | Ultrapure water: Resistivity 18.25 MΩ.cm@25℃, particles (>0.2μm) <1/ml. | ||||||||||
| Application | Cell culture, nuclease-free applications, polymerase chain reaction, DNA sequencing, electrophysiology, endocrine blocking analysis, immunohistochemistry, microbial culture media, pyrogen-free water, toxicology research and other biological experimental water. | Atomic absorption spectrometry, histology, effective liquid chromatography, mass spectrometer, atomic emission spectrometry, protein electrophoresis, ultrahigh pressure liquid chromatography, atomic absorption, capillary electrophoresis, clinical and biomedical laboratories, spectrophotometry, meteorological chromatography analysis , atomic absorption spectrometry, integrated circuits, chromatography mass spectrometry, TOC analysis, VOC analysis, NP analyzer, CDC, drug testing institute, quality inspection institute, environmental supervision station, university scientific research, Western blotting method and other physical and chemical tests and general biological experiments Use water. | Glass dish cleaning, titrator, particle analyzer, animal water, water cluster box, autoclave, biochemical oxygen demand, dissolution test, gene chip analysis, heating pot, hydroponics, Kedar analysis, pH value Water for basic physical and chemical experiments such as measurement, stability test, surface tension experiment, and wind erosion resistance Tester. | |||||||||
| power supply | 100-240VA, 50-60Hz, 300VA | 100-240VA, 50-60Hz, 300VA | 100-240VA, 50-60Hz, 300VA | |||||||||
| Overall dimensions (mm) | HxWxDï¼650x450x550 | HxWxDï¼650x450x550 | HxWxDï¼650x450x550 | |||||||||