AOLILONG PHB-5 pen pH meter laboratory test site, water quality assurance, industrial and mining production process and other ph value monitoring
SE
Measurement range 0~14.0pH, PH Measurement accuracy +/- 0.1ph, resolution 0.1pH, suitable for laboratory test sites, irregular pH value monitoring in industrial and mining production processes, water quality assurance for fishing and animal husbandry and agriculture, and supervision of environmental drainage and wastewater quality.
Measurement range 0~14.0pH, PH Measurement accuracy +/- 0.1ph, resolution 0.1pH, suitable for laboratory test sites, irregular pH value monitoring in industrial and mining production processes, water quality assurance for fishing and animal husbandry and agriculture, and supervision of environmental drainage and wastewater quality.
Introduction to PHB-5 Pen Type pH Meter
The PHB-5 pen pH meter is a portable pH meter with built-in electrodes. It uses a DC9V battery with a resolution of 0.1pH and a pH range of 0~14.0pH.
The PHB-5 pen type pH meter is a digital display portable pH meter. It has all the features of the PHB-1/2/3 portable pH meter. Due to the improvement of the internal structure, in addition to being smaller and easier to carry, it also eliminates the need for The connecting cable between the electrode and the pen-type pH meter is eliminated , making the two integrated, reducing external electric field interference and improving the stability of the reading.
Application of PHB-5 pen type pH meter
The PHB-5 pen type pH meter is particularly suitable for testing sites in research laboratories, irregular pH monitoring of industrial and mining production processes, water quality assurance in fishery, animal husbandry and agriculture, as well as environmental protection drainage and supervision of drainage water quality. It has a wide range of uses.
[Note]Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
QDoes your acidity meter have 18 major languages in the world that can be switched?
A
No.
QDo you need to calibrate the ph meter before each use?
A
Twice a week.
QIs this pen pH meter JB/T6858 compliant?
A
This pen pH meter is suitable for JB/T6858, please consult customer service for detailed application definition
QHow to use this "slope regulator"?
A
Hello, measure the positioning of the 6.86pH standard liquid adjustment instrument; measure the slope of the 4.00/9. 18pH standard liquid adjustment instrument.
Slope calibrate: insert the electrode into the buffer solution of pH 4.00 (25 ° C) and 9.18 (25 ° C), (use pH 4.00 when measuring acidic solutions; use pH 9.18 when measuring alkaline), and adjust the instrument "slope" with professional tools to make the instrument display the nominal pH value of the solution at that temperature (see Solution Encasement for the pH value of the standard buffer solution at different temperatures). Calibrate ends. To obtain accurate measurement results, the temperature of the water sample to be measured should be consistent with the buffer temperature at the time of calibration