China

FANGRUI instrument JCY-4 Contact Angle Analyzer, both inclined platform and measured surface tension

SE
FANGRUI instrument JCY-4 Contact Angle Analyzer is a multi-functional Contact Angle Analyzer, JCY-4 measurement of forward/backward angle, sliding angle of the inclined platform, the surface tension Measurement Instrument test range of 0~400mN/m.
$3882.00/set
PromotionLoading...
Coupon
Model:

FangRui JCY-4 Contact Angle AnalyzerSPEC

FangRui JCY-4 Contact Angle AnalyzerDetails

FangRui JCY-4 Contact Angle AnalyzerPacking list

SKU
NB008781
Camera system
Professional CCD Digital Camera + High Performance Microscope Head
Highest resolution
1280×1024
How to take pictures
Single sheet, continuous
light source
LED cold light source with continuously adjustable brightness, uniform light emission, clearer image outline and higher resolution
Contact angle analysis method
Theta/2 method, tangent method, automatic calculation or manual (modified) calculation
Contact angle Measurement range
0~180°
Contact angle test resolution
0.01°
Solid surface energy
Calculation of surface free energy, droplet Volume and solid adhesion by one-liquid method and two-liquid method
Surface tension test method
S-H table method, form factor method
Surface tension Measurement range
0~400mN/m
resolution
0.01mN/m
Sample stage displacement
Front and rear: 60mm; left and right 35mm; up and down 50mm, the sample table can be adjusted horizontally, the diameter is 90mm
Sample stage size
105×120mm
Sample Maximum Film thickness
≤35mm
Tilt platform
Measurement of forward/backward angle, slip angle
Injection method
Manual Sample injector
Dimensions
525*160*470mm
Net Weight
12kg
Power
220V/50Hz
Standards
ASTM D 724、ASTM D 5946、ISO15969
power
0.2KW
Surface tension Measurement range
0~400mN/m
JCY-4
Contact Angle Analyzer
FANGRUI instrument JCY-4 Contact Angle Analyzer, both inclined platform and measured surface tension Picture

JCY series Contact Angle Analyzer is a standard instrument for measuring the contact angle surface energy of solids and the surface tension of liquids. The test method adopted is image analysis method, through standard image analysis , CCD camera and image acquisition system are used, and at the same time, the contact angle value data is automatically analyzed by software. The application environment of the image values of various shapes of objects. The force measurement method has higher requirements for the uniformity and flatness of the material. The image analysis method can be used to test the surface tension value of samples under high temperature conditions, such as melted polymers.

main features

1. Using a new CCD camera system, the image of the measured droplet can be clearly displayed on the computer screen for high-precision contact angle analysis and measurement. The highest resolution of the camera: 1280×1024, frame rate: 15 or 45/ Second

2. High-precision level control, hardware level correction and software level correction (curve baseline correction) combined to achieve more accurate level alignment of the contact angle curve

3. The aviation aluminum body is adopted, which is both light and stable

4. Automatic calculation of contact angle, left and right contact angle comparison function

5. Dynamic contact angle analysis system, including analysis of contact angle changing with time, advancing angle/receding angle, inclination angle and roll angle analysis

6. Estimation of solid surface energy: Fowkes one-liquid method, Owen two-liquid method, Zisman method, Acid-Base method and other surface free energy estimation

7. The software  comes with a brightness correction function to modify the image brightness

8. Various test methods: pendant drop method, sessile drop method (static drop method);

9. Surface tension measurement: Pendant drop method (Young's equation) to measure liquid surface tension

10. Database management functions: query, backup, compression, export EXCEL form

11. The operation calculation software is based on WIN XP, VIAST system

equipment structure

1. Rack 2. Storage table 3. Knob for front and rear movement of storage table 4. Knob for up and down movement of storage table 5. Backlight screen brightness. Adjustment knob 6. Backlight screen 7. Left and right adjustment of sample rack 8. Up and down adjustment of sample rack 9 . Micro-adjustment of sample rack angle 10. Sample liquid injection knob 11. Sample needle 12. Industrial camera

Application

- During the metal welding process, detect the adhesion of the flux to the metal;

- Adhesion between ink, metal and paper in the printing industry;

- Study on the degree of adhesion between the adhesive and the solid;

- Detection of the wetting degree of aircraft substrate by rain and fog in the aerospace industry;

- Determination of the contact angle of shrapnel in air with rain and fog in military science;

- In the process of oil exploitation, the determination of the advancing angle and receding angle of the injected additive and the solid in the crude oil;

- Determination and research of wettability between nanomaterials and different active agents;

- Determination of the hydrophilic angle of aluminum foil;

Model Selection

JCY series contact angle Tester

Pictures

Optional

FAQ
QDoes the contact angle tester need to be connected to a computer?
A Yes, you need to use a computer.
Knowledge
Standard