China

NIRUN HBDV-T2 Digital Viscometer Viscosity Range 800~80000000MPa · s

SE
Digital display, Measurement range 800~80000000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage AC100-240V, 50Hz/60Hz, DC17V1.2A, Interface RS232.
Model:
Certificate

NiRun HBDV-T2 Digital ViscometerSPEC

NiRun HBDV-T2 Digital ViscometerDetails

NiRun HBDV-T2 Digital ViscometerPacking list

SKU
NB008862
Display
digital display
Measuring range
800~80000000mPa·s
Rotor Specifications
SC4-21, 27, 28, 29
Rotor speed
0.1~200rpm
Reproducibility
±0.5%F.S
Measurement Accuracy
±1%
Power
AC100-240V,50Hz/60Hz,DC17V1.2A
Data Interface
RS232
Weight
20kg
Temperature range
-1~150℃
Encasement material
Five-layer cardboard
Collection method
continuous acquisition
Capacity
2~16ml
Lifting system
Metal lifting system
Bearing system
ruby
Torque material
beryllium bronze
Control system
microcomputer
software system
DV-T2 data collection and programmable analysis software
Speed control method
CVT
HBDV-T2
Digital Viscometer
Digital display, Measurement range 800~80000000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage AC100-240V, 50Hz/60Hz, DC17V1.2A, Interface RS232.
NIRUN HBDV-T2 Digital Viscometer Viscosity Range 800~80000000MPa · s Picture

Introduction

NIRUN HBDV-T2 digital display viscometer is an integrated viscosity and temperature control machine, which integrates viscosity measurement and precise temperature control in one. It breaks through the existing market that has a constant temperature Water Tank, a viscosity measuring instrument, and a small amount of sample adapter to form a split machine. The all-in-one viscosity measurement system is composed of a small sample adapter (SSR) cylindrical sample sleeve and SC4 rotor, which can perform accurate measurement at a certain shear rate. The sample volume only needs 2 to 16m, and the SC4 rotor has a cylindrical geometry. Can provide very accurate viscosity measurement, and can get accurate shear rate data. The small sample cylinder is easy to load and unload, which brings convenience to the cleaning work. The small-volume sample cylinder is closely connected with the temperature controller, so that the temperature of the sample can be kept very accurately. The stirring action of the rotor, combined with the small sample volume, minimizes sample temperature non-uniformity. The constant temperature time is greatly shortened.

Precise temperature control is very helpful for testing the performance changes of your samples and predicting the behavior of products. Controlling the temperature when measuring the viscosity helps to ensure the accuracy of the experimental results. Since the temperature controller is composed of a semiconductor and a built-in automatic optimization temperature program control, the temperature rise/fall is adjustable, and the temperature control accuracy is ±0.1. Temperature control is operated by DV-T2 data acquisition and program-controlled analysis software, which has good operational performance and flexibility. DV-T2 data acquisition and program-controlled analysis software can do rheological curve analysis.

Product Structure

NIRUN HBDV-T2 digital display viscometer front structure diagram

NIRUN HBDV-T2 digital display viscometer back structure diagram

NIRUN HBDV-T2 digital display viscometer connecting rod structure diagram

Pictures

NIRUN HBDV-T2 digital display viscometer display

Comparison of DV-T2 Viscometer Series Parameters

modelLDV-T2RDV-T2HADV-T2HBDV-T2
Range mPa·s5-1 million25-10 million50-20 million2-80 million
Rotor speed0.1~200 rpm (continuously variable speed)
Number of rotorsStandard configuration SC4-21, 27, 28, 29 (optional rotor SC4-14, 15, 16, 18, 25, 31, 34)
sample size2-16ml
temperature range-1°C-150°C (temperature control accuracy ±0.1°C)
repeatability0.5% F/S
measurement accuracy±1.0 F/S
FAQ
QWhat is the difference between HBDV-T2 and HACV-T2 Viscometers?
A Hello, the main difference between the two models you mentioned is the difference in the viscosity range of measurement. The viscosity range of the HB series is generally larger than that of the HA series. The viscosity range of HBDV-T2 is 2 to 80 million mpa.s, while the viscosity range of HACV-T2 is 50 to 20 million mpa.s.
QMeet JJG1002 Digital Viscometer
A HBDV-T2 Digital Viscometer, please refer to it.
QWhat is the temperature range and sample test capacity of Nirun HBDV-T2?
A Hello, the temperature range that this digital display Viscometer can measure is -1~ 150 ℃, and the test volume of the sample is 2~ 16ml.
Knowledge
Standard