All Potentiometric titrator
Status
All Active Abolish Replaced Incoming Convert to industry standard
Category
Number Year
Name

HB 20056.4-2011 《Methods for analysis of Sn-Bi alloy plating and plating Sn-Bi alloy solutions.Part 4: Determination of stannous sulfate content by potentiometric titrimetric method》 Related products

HB 20056.4-2011 "Sn-bismuth alloy platings and Eletroplating tin-bismuth alloy solution analysis method, Part 4: Potential Titrimetric method for the determination of stannous sulfate content" The principle, reagents, instruments, analytical steps and result calculation methods for the determination of stannous sulfate content in Eletroplating tin-bismuth alloy solution by potential Titrimetric method are specified. This part applies to the determination of stannous sulfate content in Eletroplating tin-bismuth alloy solution. Measurement range is 30g/L~ 65g/L. In the analysis process, the use of iodine solution of tin oxidation to tetravalent tin, platinum electrode and saturated Calomel electrode for Potentiometric titration, poten-tiometry, and finally calculated according to the titration results of stannous sulfate content. This standard refers to "Metal plating and chemical covering solution analysis reagents" (HB/Z5083-2001), requiring the use of reagents and instruments that meet its requirements for analysis.

This summary is not the original standard text and is for reference only. For accurate information, please obtain it through official channels.
Status Active
CCS (H13) 重金属及其合金分析方法
ICS
Release Date 2011-07-19 00:00:00
Implementation Date 2011-10-01 00:00:00
Sort Filter
Extended reading