This standard specifies the method for the determination of tin content in sponge titanium, titanium and titanium alloys, and the applicable range is 0.05% to 12.00% of tin content. Method 1 is the potassium iodate Titrimetric method, and the determination range is 1.00% to 12.00%; Method 2 is the Inductance coupled plasma atomic emission spectroscopy (AES) method, which is an arbitration analysis method, and the applicable range is 0.05% to 12.00%. The standard details the sample dissolving, titration process and the treatment of interfering factors to ensure the accuracy of tin content determination.
| Status | Active |
|---|---|
| CCS | H14 | ICS | 77.120.50 |
| Release Date | 2017-09-29 00:00:00 | Implementation Date | 2018-04-01 00:00:00 |