Model:

JENCO 6308CST Conductivity salinity temperature controllerSPEC

JENCO 6308CST Conductivity salinity temperature controllerDetails

JENCO 6308CST Conductivity salinity temperature controllerPacking list

SKU
NB002961
Conductivity range
0uS/cm~200.0mS/cm
EC resolution
1uS/cm
Measurement Accuracy of conductivity
0.5% FS
Salinity range
0.0~70.0ppt
Salinity resolution
0.1ppt
Measurement Accuracy of salinity
0.1ppt
Measurement range
-10.0~120.0℃
Temperature Resolution
0.1℃
Measurement Accuracy
±0.3℃
Electrode type
K = 0.475 four-wire (ring) electrode
current output
A set of 4~ 20mA reversible, isolated current outputs
Insulation Voltage/maximum load
500VDC/550Ω
Relay Control Output/Maximum Load
Two sets of ON/OFF control in the system/2.5A/230VAC
protective measures
4-Digit password protection
Power Supply
110或230VAC,50/60Hz
opening size
92*92mm
Dimensions
96*96*148mm
Shop Accessories
Conductivity electrode, sheath, sealing box
6308CST
Conductivity salinity temperature controller
JENCO 6308CST online conductivity salinity temperature controller Picture

Introducing the JENCO 6308CST Online Conductivity Salinity Temperature Controller

1/4" in-line measuring instrument that displays both measured and temperature values. The instrument comes with relay control function, 4-20mA output, RS485 protocol. The instrument can be wall-mounted and dial-mounted.

Features

  1. Standard 1/4 DIN waterproof body design correction value power-off memory function.

  2. Liquid crystal display, which can display conductivity (salinity) value and temperature value at the same time.

  3. 4~20mA reversible, with isolated current output, the output range can be set by the user.

  4. 2 sets of conductivity (salinity) relay control, control point/hysteresis width can be set by the user.

  5. RS-485 communication is adopted

  6. It has the function of automatic temperature compensation.

  7. 4-wire (ring) electrode.

  8. Waterproof body design.

  9. The products have passed CE certification

JENCO 6308CST Online Conductivity Salinity Temperature Controller

Jenco 6308CST Optional Accessories

Optional
Sheath tube009A1 meter tube length
Sealed box011-200-00Dial-mounted
012-200-00Wall-mounted
FAQ
QDoes the testing process require a drug Stir probe?
A Hello, proper Stir of Ren's 6308CST probe during use can ensure more accurate measurement.
QRen's 6308CST correction, will the relay control value change?
A Hello, during the correction/setting process, the relay control/isolation current output is locked, and the original control value and current output value will not change with the correction/setting input. The display screen lock will not be lifted until the correction/setting setting is completed and returned to normal.
QRen's 6308CST Conductivity detector salinity temperature controller using what electrode?
A Hello, jenco 6308CST adopts 4 wire (ring) electrode.