GB/T 8704.8-2009 《Ferrovanadium - Determination of aluminium content - The chromazurol S spectrophotometric method and EDTA titrimetric method》 Related products

This standard specifies two methods for the determination of aluminum content in ferrovanadium: chromium azure S Spectrophotometric method, spectra-trophotometry and EDTA Titrimetric method. The chromium azure S Spectrophotometric method, spectra-trophotometry is suitable for the range of aluminum content from 0.10% to 0.80%. The aluminum content is determined by forming a colored ligand between aluminum and chromium azure S and measuring Absorbance at a wavelength of 550 nm. The EDTA Titrimetric method is suitable for the range of aluminum content from 0.50% to 3.50%. EDTA titration is used to determine the mass of aluminum. These methods provide a reliable technical basis for the accurate analysis of vanadium ferroaluminum content.

This summary is not the original standard text and is for reference only. For accurate information, please obtain it through official channels.
Status Active
CCS H11
ICS 77.100
Release Date 2009-07-15 00:00:00
Implementation Date 2010-04-01 00:00:00